Contactless measurement

Definition and Delimitation

In a non-contact measurement, no component is in the material flow or product. Measurement is done from the outside: optically, for example with near-infrared, via microwave or radar signals, or via strain gauges on the supporting structure of a container or silo. In the case of bulk materials, the term is often equated with "wear-free" or "without moving parts." This is not the same. A method without moving parts can still have a measuring surface in the flow that is touched by the material. A non-contact method has no product contact at all. Both groups have similar advantages but differ in their application limits.

Advantages in Agriculture

What is not in the material flow does not wear out. This is especially important for abrasive goods, as a worn component will deliver a different measurement value over time. In dust-prone areas, mechanically moving parts are eliminated as a potential ignition source due to friction or impact. For seeds and pellets, the product is preserved because no contact causes breakage.

Limits

Non-contact methods often react more sensitively to the installation situation, material distribution in the cross-section, and fluctuating product properties. Many initially provide a relative signal. They only yield a reliable absolute value when calibrated against a reference.

Connection with Sampling and Reference Analysis

This is where the most important connection with sampling lies. Non-contact inline methods, for example for the moisture of grain, are suitable for ongoing operations. However, their calibration depends on a laboratory value derived from a representative sample. If this sample is not representative or has absorbed moisture on the way to the lab, the inline device will permanently adopt this error. Thus, non-contact measurement does not replace sampling; it requires good sampling.

This fits with closed sampling according to the principle of containment. It keeps the sample free from ambient moisture and foreign substances and the product in the process. Non-contact measurement and closed sampling follow the same principle: The process is opened and altered as little as possible.

Non-Contact Measurement at REMBE® Kersting

The portfolio of REMBE® Kersting includes both groups. The strain gauges MicroCell and L-Cell measure externally on the supporting structure and thus completely without product contact. The VASOMETER® and the flow meter C-LEVER® operate without moving parts in the material flow and are therefore low-wear. For the samples against which inline methods are calibrated, there are representative and closed samplers like the cup sampler SAMglide and the containment sampler SAMsafe. The zone classification is determined by the operator. The execution is carried out ATEX-compliant on this basis.